Before sparkling wine is bottled, it is subjected to cross-flow microfiltration. The ITM-4 monitors the filtration quality at the CF filter outlet.
The requirement
Ideally, a filter cake is not formed during cross-flow filtration. The filtrate and permeate are permanently separated without requiring filter cleaning. Since this best case scenario depends on various parameters (such as chemical properties, transmembrane pressure differences, etc.) and can never be achieved to 100 %, sparkling wine purity must be monitored by a reliable method. Until now, this was done by visually checking the filter.
The Negele solution
The ITM-4 continuously monitors sparkling wine purity at the filter outlet prior to bottling. The tolerated limit value is between 0.2 and 0.5 NTU, depending on the sparkling wine variety. If the limit value is exceeded, the bottling process is halted immediately and the filter is cleaned.
The advantages
Changing to this automatic solution guarantees constant product quality
In addition, it leads to time savings by eliminating the need for repeated visual monitoring.
Why the Schlosskellerei Affaltrach chose NEGELE
The four-beam principle offers high measurement accuracy at very low turbidities, independent of the shape and size of the particles.
In addition to a standard signal of 4...20 mA, the device has a programmable switch output
The compact unit, made of high quality materials and accompanied by powerful electronics, offers an excellent price-performance ratio compared to similardevices on the market.
津ICP备09013498号-28 版权 © 2022 Anderson-Negele
申泰柯精密技术(天津)有限公司